Sign In | Join Free | My burrillandco.com
Home > FM200 Gas Suppression System >

Automatic Internal Storage Pressure Fire Suppression System For Large Area Coverage

    Buy cheap Automatic Internal Storage Pressure Fire Suppression System For Large Area Coverage from wholesalers
     
    Buy cheap Automatic Internal Storage Pressure Fire Suppression System For Large Area Coverage from wholesalers
    • Buy cheap Automatic Internal Storage Pressure Fire Suppression System For Large Area Coverage from wholesalers
    • Buy cheap Automatic Internal Storage Pressure Fire Suppression System For Large Area Coverage from wholesalers

    Automatic Internal Storage Pressure Fire Suppression System For Large Area Coverage

    Ask Lasest Price
    Brand Name : xinlin
    Model Number : QMQ5.6/90N-XL-004
    Certification : UL,FM,CMA,CNAS
    Price : negotiation
    Payment Terms : L/C,D/A,D/P,T/T,Western Union,MoneyGram
    Supply Ability : 20000 sets per week
    Delivery Time : 10-15 working days after payment or receipt of L/C
    • Product Details
    • Company Profile

    Automatic Internal Storage Pressure Fire Suppression System For Large Area Coverage

    Automatic Internal Storage Pressure Fire Suppression System For Large Area Coverage

    Product Description:

    Heptafluoropropane (HFC-227ea/FM-200) is a colorless, odorless, non-conductive, and no

    secondary pollution gas with clean, low toxicity, good electrical insulation, high fire-extinguishing efficiency, particularly its non-ozone destruction , the residence time in the atmosphere is relatively short, its environmental performance is superior to Halon, is by far the more successful research and development of a clean gas extinguishing agent, can be used safely in the workplace has staff also replace Halon's most 1301,1211 one of the ideal product.

    Technical Parameters:

    Product NameFM200 System
    Filling pressure4.2 MPa
    Starting ModeAutomatic, Electrical Manual, Mechanical Emergency
    System Power SupplyAC220V/DC24V/1A
    Filling Density≤1080kg/m3
    Scope of Work0°C~50°C
    Storage bottle volume90L, 120L,150L, 180L
    System Blowdown TimeComputer Room ≤8s, Other ≤10s
    Maximum Working Pressure5.3MPA(+20°C)



    Applications:


    Automatic suppression systems based on the FM200 are used in critical areas of significant strategic value. Critical areas are those that house high-cost investment elements and/or are fundamental to the operation of a company or even society.

    The FM200 gas system is widely used to protect:

    · Process control rooms in refineries, gas plants, power plants, petrochemical plants, etc.

    · Substations at power distribution companies and refineries

    · Substations at train and subway stations

    · Railway signal rooms

    · Electrical rooms or distribution rooms

    · Server rooms

    · Telecommunications rooms or communication centers for internet service providers and mobile phone operators

    · Motor control centers (MCCs) in industry and other sectors

    · Data centers for banks, oil companies, mining companies, etc.

    · Permanent Gas (PTG) gas and Permanent Petroleum (PTC) oil processing facilities

    · Offshore platform facilities

    · Zoned distribution rooms

    · Airport control rooms


    Automatic Internal Storage Pressure Fire Suppression System For Large Area Coverage



    Maintenance requirement


    Check the system regularly, including the pressure check of the fire extinguishing agent bottle group, generally check the bottle group pressure at least once a month to ensure that the pressure is within the specified range. Check pipes and fittings for leakage, and use soapy water and other methods to detect leakage. It is also necessary to perform functional tests on the electrical components of the system, such as fire detectors, controllers, etc., to ensure that the system can start and operate normally. In addition, every five years should be a comprehensive test of the system, including fire extinguishing agent quality testing.


    Automatic Internal Storage Pressure Fire Suppression System For Large Area Coverage

    Why choose us:


    • Efficient management system

    • More than 10 years of experience in gas fire fighting industry

    • Advanced equipment and professional engineers

    • We provide 8×6 hr technical support and after-sales service


    Frequently Asked Questions

    -----------------------------------------------------------------------------------

    Q1Are you a manufacturer or a trading company?

    A1: We are the manufacturer.


    Q2: Do you have OEM orders?

    A2: Yes, according to the customer's requirements.


    Q3: Where is your factory located? How do I get there?

    A3: Our factory is located in Dongzhou Industrial Park, Xintang Town, Zengcheng District, Guangzhou City, Guangdong Province, China.

    You are very welcome to visit our factory.


    Quality Automatic Internal Storage Pressure Fire Suppression System For Large Area Coverage for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Guangzhou Xinlin Fire Fighting Equipment Co., Ltd.
    *Subject:
    *Message: